our products
for security vehicles

ADVANCED HVAC – LM 13 MPV
13kW @ 55°C Ambient
8kW from Vehicle Engine Water
55°C
R134a

HVAC BASIC – GILA MRAP
6kW
45°C
R134a
28V DC, 35A Evap

HVAC UNDERSEAT/FLOOR M36 APC
13-16kW versions available
-15°C to 45°C
5kW (Reverse Cycle or Engine Hot Water)
28VDC, 70A Evap; 50A for condenser side wall option

HVAC – RG35 MRAP
12kW
55°C
R134a
28V DC, 50A

TEAR GAS FILTRATION SYSTEM
8 - 100ℓ/s
-5°C to 55°C
28VDC, 16A
IP54

ROOFTOP HVAC UNIT 8kW
8kW @ 45°C Ambient
28VDC; 30A Maximum
R134a
Integrated on Vehicle Engine (Belt Driven)

ROOFTOP TEARGAS SYSTEM
STANAG 4632 (AEP-54)
170m3/h
95% Efficient Particle Cyclone Filtration; Primary Pleated Filter, HEPA with CBRN Filtration Cartridge
Pressure Regulation between 200-500Pa

SPLIT AIR CONDITIONING UNIT
24VDC @ 50A
B1 and B2 Tropical
27°C Tolerance: ± 2°C
+26°C to +44°C

STANDARD SPLIT AIRCON UNIT
5 to 8kW
10 to 16kW
No
Washable G3 Filter

Teargas Filter Unit Internal Mounted
STANAG 4632 (AEP-54)
28VDC, 30A
Fresh Air & Teargas – (motorised switch with manual override)
95% Efficient Particle Cyclone Filtration; Primary Pleated Filter, HEPA with
Teargas Filtration Cartridge
our products
for defence vehicles
Mission-ready thermal control, air-quality and power management systems designed to deliver stable environments and reliable performance in all defence vehicle applications.

HVAC ROOFTOP URBAN FORCES VEHICLES
14kW @ 55°C Ambient
55°C
R134a
144m3/h

HVAC - DCD MRAP VEHICLES
11.5kW
Operating Envelope
-10°C to 50°C
Power Supply
28V DC, 60A
Heating Capacity
7.5kW (Independent, Externally Mounted Module)

ADVANCED HVAC – LM 13 MPV
13kW @ 55°C Ambient
8kW from Vehicle Engine Water
55°C
R134a

HVAC BASIC – GILA MRAP
6kW
45°C
R134a
28V DC, 35A Evap

HVAC CABIN MODULES FOR APCS
12kW
50°C
28V DC, 80A total system
313cm³ Displacement (Engine Driven)

HVAC WITH CBRN - 8X8 AMV
12kW
12kW
Fresh Air
250m3/h normal / 170m3/h CBRN with over pressure
48°C

HVAC WITH CBRN - MARAUDER MPV
13kW (two evaporators)
5.5kW Diesel Air Heater
-50°C to 55°C
CBRN Protection
STANAG 4632 (AEP-54)

HVAC - CASSPIR MRAP
8-16kW versions available
Operating Envelope
-10°C to 50°C
AC or DC powered options
R134a

ROOFTOP HVAC UNIT 8kW
8kW @ 45°C Ambient
28VDC; 30A Maximum
R134a
Compressor
Integrated on Vehicle Engine (Belt-driven)

SPLIT AIR CONDITIONING UNIT
24VDC @ 50A
B1 and B2 Tropical
Cabin Design Temp.
27°C Tolerance: ± 2°C
+26°C to +44°C

STANDARD SPLIT AIRCON UNIT
Cooling Capacity
for single Evaporator 5 to 8kW
Cooling Capacity
for dual Evaporator 10 to 16kW
Operating envelope
From 0°C to 55°C
Filter
Washable G3 filter

MK UNITS
9-20kW (MK series MK950, MK1650, MK2000)
12kW max
Maximum Ambient
55°C
Max Input Current (@400V)
31 Amp Cooling; 27 Amp Heating

HVAC UNDERSEAT/FLOOR M36 APC
13-16kW versions available
-15°C to 45°C
5kW (Reverse Cycle or Engine Hot Water)
Power Supply
28VDC, 70A Evap; 50A for condenser side wall option

HVAC – RG35 MRAP
12kW
55°C
Refrigerant
R134a
28V DC, 50A

CBRN MASK FILTRATION SYSTEM
CBRN Protection
AEP54 Edition 2 (Oct 2014) Gas Test Compliant; STANAG 4632 (AEP-54)
Airflow
53m3/h
CBRN Filter Cartridge
Diam 300mm x 200mm AEP54 Edition 2 (Oct 2014) Gas Test Compliant
Filtration
HEPA with CBRN filtration cartridge

CBRN FILTRATION SYSTEM
Airflow Capacity
170m3/h
Operating Envelope
-45°C to 55°C
CBRN Filter Cartridge
Diam 300mm x 200mm AEP54 Edition 2 (Oct 2014) Gas Test Compliant
Filtration
HEPA with CBRN filtration cartridge

ROOFTOP TEARGAS SYSTEM
STANAG 4632 (AEP-54)
170m3/h
95% Efficient Particle Cyclone Filtration; Primary Pleated Filter, HEPA with CBRN Filtration Cartridge
Pressure Regulation between 200-500Pa

Teargas Filter Unit Internal Mounted
STANAG 4632 (AEP-54)
28VDC, 30A
Fresh Air & Teargas – (motorised switch with manual override)
95% Efficient Particle Cyclone Filtration; Primary Pleated Filter, HEPA with
Teargas Filtration Cartridge

CBRN OVERPRESSURE TROLLEY
Power Supply
230 VAC; 50Hz
170m3/h (Dependent on system/piping losses)
Overpressure Qualification
200-800 Pa
Primary - on Display Screen
Secondary - Pressure Gauge

COMPACT CBRN UNIT
CBRN Protection
AEP54 Edition 2 (October 2014) Gas Test Compliant; STANAG 4632 (AEP-54)
170m³/h
Filter Cartridge Pressure Drop
1,200 Pa Nominal (Initial); 1,700 Pa Nominal (Final)
Filtration 95% Efficient Particle Cyclone Filtration; Primary Pleated Filter, HEPA with CBRN filtration cartridge

AMV COMPACT AUXILIARY POWER UNIT
Output Power
28VDC 3,5kW @ 3000rpm
Engine Cooling
Air Cooled
Operation
APU can operate continuously with front APU door closed. (Hatches on side and bottom must be open.)
Vibration
MIL-STD-810F, Method 514.5

APU FOR URBAN FORCES VEHICLES
17kW Derated @ 2600 rpm in 55°C Ambient
Operating Envelope
-10°C to 55°C
28VDC output power
170A @ 55°C Derated (Brushless Alternator)
Fuel
Supplied from vehicle fuel tank

LOW PROFILE APU FOR MBTS
PMG Output Power
20kW derated @ 3000 rpm in 49°C Ambient
-46°C to 49°C
Cold Start Requirement
-32°C without preparations, but up to -46°C with preheating preparations
28VDC output power
20kW; 715 A @ 0m and 49°C derated. 17kW; 608 A @ 4500m and -10°C derated

M109 HOWITZER APU
Output Power Capacity
21kW derated @ 2600rpm in 55°C Ambient
-10°C to 55°C
10 Hours (80 Litres)
28VDC output power
230A @ 55°C (Brushless Alternator)

MODULAR ELECTRIC & HYDRAULIC APU
Airflow Capacity
8 - 100ℓ/s
-5°C to 55°C
Power Supply
28VDC, 16A
Environmental Protection
IP54

APU FOR DUMA RADAR VEHICLE
Output Power Capacity
11kW; 230VAC; 50Hz @ 0.8PF (Derated)
Input Voltage
28 VDC
Ambient Operating Range
-32°C to 55°C
Altitude Operating Range
Zero to 3600m

WATER CHILLER ADD-ON MODULE
Cooling Capacity
2-4kW Water Cooling Options
Reservoir
60 Litres Drinking Water
Cooling time 60l
Less than 30 mins from 30°C to 10°C
Refrigerant
R134a

BALLISTIC FUEL TANK PROTECTION
Elongation
350%
Tensile Strength
19.3MPa
Flexural Modulus
41.3MPa
Hardness
Shore A – 85

GUN SMOKE EXTRACTOR FAN
Airflow
600m3/h
Power Input
24VDC; 8A max
Rotation Speed
12000rpm
Maximum Ambient
55°C
our products
for mining & smelters
Heavy-duty thermal management, air-quality and power distribution solutions built to regulate heat, airflow and electrical demand in extreme mining conditions.

MK 500
400V ±20%, 50Hz. Double insulated
5.0kW
65°C
8A

PC 075
230V ±10%, 50Hz
0.75kW
65°C
400V 3A

MK 950
400V ±20%, 50Hz. Double insulated
9,5kW
65°C
16A

PC 150
230V ±10%, 50Hz
1.5kW
65°C
400V 6A

MK 1650
400V ±20%, 50Hz. Double insulated
16,5kW
65°C
26,3A

PC 300
230V ±10%, 50Hz
3.0kW
65°C
400V 12A

MK 2000
400V ±20%, 50Hz. Double insulated
20kW
55°C
28,9A

PC 450
230V ±10%, 50Hz
5.0kW
65°C
400V 19A
our products
for containers & shelters
Integrated thermal, air-quality and power management units providing dependable environment control and efficient energy distribution for containerised and mobile shelters.

EXPANDABLE CONTAINER SOLUTIONS
Standard AC 3 phase/1 phase as per load requirement
Lighting inside
24V LED lighting powered from a converter inside the DB
Footprint in packed state
6058mm L x 2438mm W x 2438/2591mm H (outside dimensions)
Footprint in expanded state
6058mm L x 6500mm W x 2438/2591mm H (outside dimensions)

CONTINEST (Containerised HVAC Solution)
4.75kW
Heating Capacity
5.5kW
Ambient Range
-40°C to 45°C
27A @ 220VAC

RUGGEDISED SPLIT HVAC
23200 BTU (6.8kW); 32400 BTU (9.5kW)
Design Ambient 45°C
1 Phase, 50Hz, 220 - 240V

FRONT PANEL MOUNT HVAC (18E)
5.6kW
45°C
230VAC
4kW Reverse Cycle
our products
for trains & trams

EMU SALOON HVAC UNIT
22kW per side, total of 44kW @ 45°C Ambient Temperature
50°C
-10°C
400 VAC, 44 A Cooling, 36 A Heating

EMU DRIVER HVAC UNIT
4.5kW @ 45°C Ambient Temperature
50°C
400 VAC, 5.2 A Cooling, 4.9 A Heating
3kW

STREETCAR DRIVER HVAC UNIT
4.5kW @ 35°C, 50% RH
5.0kW
700 - 1100m3/h, but current design is done for 800m3/h
30 - 60m3/h, but current design is done for 60m3/h
our products
for locomotives
Rail-grade thermal management, ventilation and power distribution systems designed for stable cooling, heating and electrical reliability in locomotive environments.

CAB HVAC DIESEL LOCOS
8kW
48°C
74V DC

CAB HVAC ROOFTOP UNIT
8kW @ 45°C Ambient
45°C
74VDC; 97A Maxx

LOCO CAB HEATER
1.5kW (high setting), 0.75kW (low setting)
320m3h
400VAC; 3A

CAB 8kW HVAC
8kW @ 45°C Ambient
48°C
400V AC; 16A Max
> 1150m3/h

FRONT PANEL MOUNT HVAC (18E)
5.6kW
45°C
230VAC
4kW Reverse Cycle

MODULAR LOCO ROOFTOP HVAC (9E)
8kW @ 45°C
-10°C to 55°C
230VAC
4kW Reverse Cycle

C30 ROOFTOP HVAC 6kW
6.0kW
0°C to 45°C
R134a
74V DC
our products
for passenger coaches
Comfort-driven thermal control, air-quality and power management solutions built to maintain consistent passenger environments with optimised energy use.

CAB HVAC - CONSOLE INTEGRATED
8kW
-10°C to 55°C
74VDC to DC conversion (24V components) 75A (Evap Unit)
R134a

MODULAR COACH ROOFTOP HVAC A
40kW per coach
39.2A
R407C/R134a
-10°C to 45°C

MODULAR COACH ROOFTOP HVAC B
30kW / unit @ 60°C Ambient (60kW per coach)
65°C
-10°C
400VAC; 39A Cooling; 18A Heating

RUGGEDISED SPLIT HVAC
23200 BTU (6.8kW); 32400 BTU (9.5kW)
Design Ambient 45°C
1 Phase, 50Hz, 220 - 240V

CEILING INTEGRATED AIR HANDLING UNIT
5 to 9kW Cooling or Heating
Single or Dual Liquid Circuit
Water/Glycol
60-70kg

MODULAR DRINKING WATER COOLER
Cooling Capacity
2-4kW Water Cooling Options
Reservoir
60 Litres Drinking Water
Cooling time 60l
Less than 30 mins from 30°C to 10°C
Refrigerant
R134a
our products
for tents & field camps
Portable thermal management, clean-air and power generation solutions delivering stable, efficient environmental control for tents, field camps and temporary operational sites.

MK 500
400V ±20%, 50Hz. Double insulated
5.0kW
65°C
8A

MK 950
400V ±20%, 50Hz. Double insulated
9,5kW
65°C
16A

MK 1650
400V ±20%, 50Hz. Double insulated
16,5kW
65°C
26,3A

MK 2000
400V ±20%, 50Hz. Double insulated
20kW
55°C
28,9A