Robust products for all environments


Advanced. Rugged. Reliable

our products

for security vehicles

Advanced thermal management, air-quality and power management solutions engineered to maintain controlled, safe environments inside specialised security vehicles.
Image
ADVANCED HVAC – LM 13 MPV

Cooling Capacity
13kW @ 55°C Ambient
Heating Capacity
8kW from Vehicle Engine Water
Maximum Ambient
55°C
Refrigerant
R134a
Image
HVAC BASIC – GILA MRAP

Cooling Capacity
6kW
Maximum Ambient
45°C
Refrigerant
R134a
Power Supply
28V DC, 35A Evap
Image
HVAC UNDERSEAT/FLOOR M36 APC

Cooling Capacity
13-16kW versions available
Operating Envelope
-15°C to 45°C
Heating Capacity
5kW (Reverse Cycle or Engine Hot Water)
Power Supply
28VDC, 70A Evap; 50A for condenser side wall option
Image
HVAC – RG35 MRAP

Cooling Capacity
12kW
Maximum Ambient
55°C
Refrigerant
R134a
Power Input
28V DC, 50A
Image
TEAR GAS FILTRATION SYSTEM

Airflow Capacity
8 - 100ℓ/s
Operating Envelope
-5°C to 55°C
Power Supply
28VDC, 16A
Environmental Protection
IP54
Image
ROOFTOP HVAC UNIT 8kW

Cooling Capacity
8kW @ 45°C Ambient
Power Supply
28VDC; 30A Maximum
Refrigerant
R134a
Compressor
Integrated on Vehicle Engine (Belt Driven)
Image
ROOFTOP TEARGAS SYSTEM

CBRN Protection
STANAG 4632 (AEP-54)
Airflow
170m3/h
Filtration
95% Efficient Particle Cyclone Filtration; Primary Pleated Filter, HEPA with CBRN Filtration Cartridge
Overpressure
Pressure Regulation between 200-500Pa
SPLIT AIR CONDITIONING UNIT
SPLIT AIR CONDITIONING UNIT

Power Supply
24VDC @ 50A
Operating Environment
B1 and B2 Tropical
Cabin Design Temp.
27°C Tolerance: ± 2°C
Ambient Design Temp.
+26°C to +44°C
STANDARD SPLIT AIRCON UNIT
STANDARD SPLIT AIRCON UNIT

Cooling Capacity for single Evaporator
5 to 8kW
Cooling Capacity for dual Evaporator
10 to 16kW
Operating Environment
No
Filter
Washable G3 Filter
TEARGAS FILTER UNIT INTERNAL MOUNTED
Teargas Filter Unit Internal Mounted

Teargas Protection
STANAG 4632 (AEP-54)
Power Supply
28VDC, 30A
Modes
Fresh Air & Teargas – (motorised switch with manual override)
Filtration
95% Efficient Particle Cyclone Filtration; Primary Pleated Filter, HEPA with
Teargas Filtration Cartridge

our products

for defence vehicles

Mission-ready thermal control, air-quality and power management systems designed to deliver stable environments and reliable performance in all defence vehicle applications.

Image
HVAC ROOFTOP URBAN FORCES VEHICLES

Cooling Capacity
14kW @ 55°C Ambient
Maximum Ambient
55°C
Refrigerant
R134a
Fresh Air Supply
144m3/h
Image
HVAC - DCD MRAP VEHICLES

Cooling Capacity
11.5kW

Operating Envelope
-10°C to 50°C

Power Supply
28V DC, 60A

Heating Capacity
7.5kW (Independent, Externally Mounted Module)

Image
ADVANCED HVAC – LM 13 MPV

Cooling Capacity
13kW @ 55°C Ambient
Heating Capacity
8kW from Vehicle Engine Water
Maximum Ambient
55°C
Refrigerant
R134a
Image
HVAC BASIC – GILA MRAP

Cooling Capacity
6kW
Maximum Ambient
45°C
Refrigerant
R134a
Power Supply
28V DC, 35A Evap
Image
HVAC CABIN MODULES FOR APCS

Cooling Capacity
12kW
Maximum Ambient
50°C
Power Supply
28V DC, 80A total system
Compressor
313cm³ Displacement (Engine Driven)
Image
HVAC WITH CBRN - 8X8 AMV

Cooling Capacity
12kW
Heating Capacity
12kW

Fresh Air
250m3/h normal / 170m3/h CBRN with over pressure

Maximum Ambient
48°C
Image
HVAC WITH CBRN - MARAUDER MPV

Cooling Capacity
13kW (two evaporators)
Heating Capacity
5.5kW Diesel Air Heater
Ambient
-50°C to 55°C

CBRN Protection
STANAG 4632 (AEP-54)

Image
HVAC - CASSPIR MRAP

Cooling Capacity
8-16kW versions available

Operating Envelope
-10°C to 50°C

Power Supply
AC or DC powered options
Refrigerant
R134a
Image
ROOFTOP HVAC UNIT 8kW

Cooling Capacity
8kW @ 45°C Ambient
Power Supply
28VDC; 30A Maximum
Refrigerant
R134a

Compressor
Integrated on Vehicle Engine (Belt-driven)

Image
SPLIT AIR CONDITIONING UNIT

Power Supply
24VDC @ 50A
Operating Environment
B1 and B2 Tropical

Cabin Design Temp.
27°C Tolerance: ± 2°C

Ambient Design Temp.
+26°C to +44°C
Image
STANDARD SPLIT AIRCON UNIT

Cooling Capacity
for single Evaporator 5 to 8kW

Cooling Capacity
for dual Evaporator 10 to 16kW

Operating envelope
From 0°C to 55°C

Filter
Washable G3 filter

Image
MK UNITS

Cooling Capacity
9-20kW (MK series MK950, MK1650, MK2000)
Heating Capacity
12kW max

Maximum Ambient
55°C

Max Input Current (@400V)
31 Amp Cooling; 27 Amp Heating

Image
HVAC UNDERSEAT/FLOOR M36 APC

Cooling Capacity
13-16kW versions available
Operating envelope
-15°C to 45°C
Heating Capacity
5kW (Reverse Cycle or Engine Hot Water)

Power Supply
28VDC, 70A Evap; 50A for condenser side wall option

Image
HVAC – RG35 MRAP

Cooling Capacity
12kW
Maximum Ambient
55°C

Refrigerant
R134a

Power Input
28V DC, 50A
Image
CBRN MASK FILTRATION SYSTEM

CBRN Protection
AEP54 Edition 2 (Oct 2014) Gas Test Compliant; STANAG 4632 (AEP-54)

Airflow
53m3/h

CBRN Filter Cartridge
Diam 300mm x 200mm AEP54 Edition 2 (Oct 2014) Gas Test Compliant

Filtration
HEPA with CBRN filtration cartridge

Image
CBRN FILTRATION SYSTEM

Airflow Capacity
170m3/h

Operating Envelope
-45°C to 55°C

CBRN Filter Cartridge
Diam 300mm x 200mm AEP54 Edition 2 (Oct 2014) Gas Test Compliant

Filtration
HEPA with CBRN filtration cartridge

Image
ROOFTOP TEARGAS SYSTEM

CBRN Protection
STANAG 4632 (AEP-54)
Airflow
170m3/h
Filtration
95% Efficient Particle Cyclone Filtration; Primary Pleated Filter, HEPA with CBRN Filtration Cartridge
Overpressure
Pressure Regulation between 200-500Pa
Image
Teargas Filter Unit Internal Mounted

Teargas Protection
STANAG 4632 (AEP-54)
Power Supply
28VDC, 30A
Modes
Fresh Air & Teargas – (motorised switch with manual override)
Filtration
95% Efficient Particle Cyclone Filtration; Primary Pleated Filter, HEPA with
Teargas Filtration Cartridge
CBRN OVERPRESSURE TROLLEY
CBRN OVERPRESSURE TROLLEY

Power Supply
230 VAC; 50Hz

Max Airflow
170m3/h (Dependent on system/piping losses)

Overpressure Qualification
200-800 Pa

Overpressure Indication
Primary - on Display Screen
Secondary - Pressure Gauge
COMPACT CBRN UNIT
COMPACT CBRN UNIT

CBRN Protection
AEP54 Edition 2 (October 2014) Gas Test Compliant; STANAG 4632 (AEP-54)

Airflow
170m³/h

Filter Cartridge Pressure Drop
1,200 Pa Nominal (Initial); 1,700 Pa Nominal (Final)

Filtration
Filtration 95% Efficient Particle Cyclone Filtration; Primary Pleated Filter, HEPA with CBRN filtration cartridge
AMV COMPACT AUXILIARY POWER UNIT
AMV COMPACT AUXILIARY POWER UNIT

Output Power
28VDC 3,5kW @ 3000rpm

Engine Cooling
Air Cooled

Operation
APU can operate continuously with front APU door closed. (Hatches on side and bottom must be open.)

Vibration
MIL-STD-810F, Method 514.5

APU FOR URBAN FORCES VEHICLES
APU FOR URBAN FORCES VEHICLES

Output Power Capacity
17kW Derated @ 2600 rpm in 55°C Ambient

Operating Envelope
-10°C to 55°C

28VDC output power
170A @ 55°C Derated (Brushless Alternator)

Fuel
Supplied from vehicle fuel tank

LOW PROFILE APU FOR MBTS
LOW PROFILE APU FOR MBTS

PMG Output Power
20kW derated @ 3000 rpm in 49°C Ambient

Operating Envelope
-46°C to 49°C

Cold Start Requirement
-32°C without preparations, but up to -46°C with preheating preparations

28VDC output power
20kW; 715 A @ 0m and 49°C derated. 17kW; 608 A @ 4500m and -10°C derated

M109 HOWITZER APU
M109 HOWITZER APU

Output Power Capacity
21kW derated @ 2600rpm in 55°C Ambient

Operating Envelope
-10°C to 55°C
Fuel
10 Hours (80 Litres)

28VDC output power
230A @ 55°C (Brushless Alternator)

MODULAR ELECTRIC & HYDRAULIC APU
MODULAR ELECTRIC & HYDRAULIC APU

Airflow Capacity
8 - 100ℓ/s

Operating Envelope
-5°C to 55°C

Power Supply
28VDC, 16A

Environmental Protection
IP54

APU FOR DUMA RADAR VEHICLE
APU FOR DUMA RADAR VEHICLE

Output Power Capacity
11kW; 230VAC; 50Hz @ 0.8PF (Derated)

Input Voltage
28 VDC

Ambient Operating Range
-32°C to 55°C

Altitude Operating Range
Zero to 3600m

WATER CHILLER ADD-ON MODULE
WATER CHILLER ADD-ON MODULE

Cooling Capacity
2-4kW Water Cooling Options

Reservoir
60 Litres Drinking Water

Cooling time 60l
Less than 30 mins from 30°C to 10°C

Refrigerant
R134a

BALLISTIC FUEL TANK PROTECTION
BALLISTIC FUEL TANK PROTECTION

Elongation
350%

Tensile Strength
19.3MPa

Flexural Modulus
41.3MPa

Hardness
Shore A – 85

GUN SMOKE EXTRACTOR FAN
GUN SMOKE EXTRACTOR FAN

Airflow
600m3/h

Power Input
24VDC; 8A max

Rotation Speed
12000rpm

Maximum Ambient
55°C

our products

for mining & smelters

Heavy-duty thermal management, air-quality and power distribution solutions built to regulate heat, airflow and electrical demand in extreme mining conditions.

Image
MK 500

Electrical supply
400V ±20%, 50Hz. Double insulated
Cooling Capacity
5.0kW
Maximum Ambient
65°C
Max Input Current @ 400V
8A
Image
PC 075

Electrical supply
230V ±10%, 50Hz
Cooling Capacity
0.75kW
Maximum Ambient
65°C
Max Input Current
400V 3A
Image
MK 950

Electrical Supply
400V ±20%, 50Hz. Double insulated
Cooling Capacity
9,5kW
Maximum Ambient
65°C
Max Input Current @ 400V
16A
Image
PC 150

Electrical supply
230V ±10%, 50Hz
Cooling Capacity
1.5kW
Maximum Ambient
65°C
Max Input Current
400V 6A
Image
MK 1650

Electrical supply
400V ±20%, 50Hz. Double insulated
Cooling Capacity
16,5kW
Maximum Ambient
65°C
Max Input Current @ 400V
26,3A
Image
PC 300

Electrical supply
230V ±10%, 50Hz
Cooling Capacity
3.0kW
Maximum Ambient
65°C
Max Input Current
400V 12A
Image
MK 2000

Electrical Supply
400V ±20%, 50Hz. Double insulated
Cooling Capacity
20kW
Maximum Ambient
55°C
Max Input Current @ 400V
28,9A
Image
PC 450

Electrical supply
230V ±10%, 50Hz
Cooling Capacity
5.0kW
Maximum Ambient
65°C
Max Input Current
400V 19A

our products

for containers & shelters

Integrated thermal, air-quality and power management units providing dependable environment control and efficient energy distribution for containerised and mobile shelters.

expandable container solutions
EXPANDABLE CONTAINER SOLUTIONS

Electrical supply
Standard AC 3 phase/1 phase as per load requirement

Lighting inside
24V LED lighting powered from a converter inside the DB

Footprint in packed state
6058mm L x 2438mm W x 2438/2591mm H (outside dimensions)

Footprint in expanded state
6058mm L x 6500mm W x 2438/2591mm H (outside dimensions)

Image
CONTINEST (Containerised HVAC Solution)

Cooling Capacity
4.75kW

Heating Capacity
5.5kW

Ambient Range
-40°C to 45°C

Max Input Current
27A @ 220VAC
Image
RUGGEDISED SPLIT HVAC

7,5kW Split System with Reverse Cycle Function
Cooling Capacity
23200 BTU (6.8kW); 32400 BTU (9.5kW)
Environmental
Design Ambient 45°C
Power Supply
1 Phase, 50Hz, 220 - 240V
Image
FRONT PANEL MOUNT HVAC (18E)

Cooling Capacity
5.6kW
Maximum Ambient
45°C
Power Supply
230VAC
Heating
4kW Reverse Cycle

our products

for trains & trams

High-efficiency thermal comfort, air-quality and power management systems engineered to ensure reliable climate control and energy optimisation on modern rail vehicles.
Image
EMU SALOON HVAC UNIT

Cooling Capacity
22kW per side, total of 44kW @ 45°C Ambient Temperature
Maximum Ambient
50°C
Minimum Ambient
-10°C
System Power Input
400 VAC, 44 A Cooling, 36 A Heating
Image
EMU DRIVER HVAC UNIT

Cooling Capacity
4.5kW @ 45°C Ambient Temperature
Maximum Ambient
50°C
System Power Input
400 VAC, 5.2 A Cooling, 4.9 A Heating
Heating Capacity
3kW
Image
STREETCAR DRIVER HVAC UNIT

Cooling Capacity
4.5kW @ 35°C, 50% RH
Heating Capacity
5.0kW
Recirculation
700 - 1100m3/h, but current design is done for 800m3/h
Fresh Air
30 - 60m3/h, but current design is done for 60m3/h

our products

for locomotives

Rail-grade thermal management, ventilation and power distribution systems designed for stable cooling, heating and electrical reliability in locomotive environments.

Image
CAB HVAC DIESEL LOCOS

8kW Locomotive Aircon System with Integrated Unico 74V DC Inverter
Cooling Capacity
8kW
Maximum Ambient
48°C
Power Supply
74V DC
Image
CAB HVAC ROOFTOP UNIT

8kW Rooftop Air Conditioning Unit (ACU) for Diesel Locomotive
Cooling Capacity
8kW @ 45°C Ambient
Maximum Ambient
45°C
System Power Input
74VDC; 97A Maxx
Image
LOCO CAB HEATER

1.5kW Foot Heater for Diesel/Electric Locomotive
Heating Capacity
1.5kW (high setting), 0.75kW (low setting)
Air Flow
320m3h
Power Input
400VAC; 3A
Image
CAB 8kW HVAC

Cooling Capacity
8kW @ 45°C Ambient
Maximum Ambient
48°C
System Power Input
400V AC; 16A Max
Aircon Air Flow Rate
> 1150m3/h
Image
FRONT PANEL MOUNT HVAC (18E)

Cooling Capacity
5.6kW
Maximum Ambient
45°C
Power Supply
230VAC
Heating
4kW Reverse Cycle
Image
MODULAR LOCO ROOFTOP HVAC (9E)

Cooling Capacity
8kW @ 45°C
Operating Envelope
-10°C to 55°C
Construction
230VAC
Heating
4kW Reverse Cycle
Image
C30 ROOFTOP HVAC 6kW

Cooling Capacity
6.0kW
Operating Envelope
0°C to 45°C
Refrigerant
R134a
Supply Power
74V DC

our products

for passenger coaches

Comfort-driven thermal control, air-quality and power management solutions built to maintain consistent passenger environments with optimised energy use.

Image
CAB HVAC - CONSOLE INTEGRATED

Cooling Capacity
8kW
Operating Envelope
-10°C to 55°C
Power Supply
74VDC to DC conversion (24V components) 75A (Evap Unit)
Refrigerant
R134a
Image
MODULAR COACH ROOFTOP HVAC A

Cooling Capacity
40kW per coach
Max Input Current (@400V)
39.2A
Refrigerant
R407C/R134a
Operating Envelope
-10°C to 45°C
Image
MODULAR COACH ROOFTOP HVAC B

Cooling Capacity
30kW / unit @ 60°C Ambient (60kW per coach)
Maximum Ambient
65°C
Minimum Ambient
-10°C
System Power Input
400VAC; 39A Cooling; 18A Heating
Image
RUGGEDISED SPLIT HVAC

7,5kW Split System with Reverse Cycle Function
Cooling Capacity
23200 BTU (6.8kW); 32400 BTU (9.5kW)
Environmental
Design Ambient 45°C
Power Supply
1 Phase, 50Hz, 220 - 240V
Image
CEILING INTEGRATED AIR HANDLING UNIT

Capacity
5 to 9kW Cooling or Heating
Configuration
Single or Dual Liquid Circuit
Circuit
Water/Glycol
Total Weight
60-70kg
Image
MODULAR DRINKING WATER COOLER

Cooling Capacity
2-4kW Water Cooling Options

Reservoir
60 Litres Drinking Water

Cooling time 60l
Less than 30 mins from 30°C to 10°C

Refrigerant
R134a

our products

for tents & field camps

Portable thermal management, clean-air and power generation solutions delivering stable, efficient environmental control for tents, field camps and temporary operational sites.

Image
MK 500

Electrical supply
400V ±20%, 50Hz. Double insulated
Cooling Capacity
5.0kW
Maximum Ambient
65°C
Max Input Current @ 400V
8A
Image
MK 950

Electrical Supply
400V ±20%, 50Hz. Double insulated
Cooling Capacity
9,5kW
Maximum Ambient
65°C
Max Input Current @ 400V
16A
Image
MK 1650

Electrical supply
400V ±20%, 50Hz. Double insulated
Cooling Capacity
16,5kW
Maximum Ambient
65°C
Max Input Current @ 400V
26,3A
Image
MK 2000

Electrical Supply
400V ±20%, 50Hz. Double insulated
Cooling Capacity
20kW
Maximum Ambient
55°C
Max Input Current @ 400V
28,9A